01 — Air Conditioning

Air Conditioning

From a single split unit to a multi-storey VRF/VRV system, AMAC designs and installs air conditioning sized to the actual load — not a rule of thumb.

Start Your Project Email Us

What this covers

VRF/VRV system design

Multi-storey and multi-tenant buildings where dozens of indoor units run independently from shared outdoor plant.

Split and multi-split installs

Single-room and whole-floor systems for offices, retail units, server rooms and domestic properties.

Load calculations

Sizing worked from the building's real heat gains — glazing, occupancy, equipment and orientation — rather than a per-square-metre shortcut.

F-Gas certified handover

Refrigerant handling, leak testing, commissioning and documentation completed to F-Gas requirements.

Which system for which building

A rough guide. The survey decides it properly, but this is the conversation we'll have.

SystemBest forZonesHeating tooCapital costWatch out for
SplitSingle room, server cupboard, small shop, bedroom1YesLowOne outdoor unit per indoor unit — wall space outside
Multi-splitTwo to five rooms off one outdoor unit2 – 5Yes, all in the same modeLow – midCan't heat one room while cooling another
VRF heat pumpOpen-plan floors, retail units, clinicsUp to 64Yes, all in the same modeMidRefrigerant charge in occupied rooms may need leak detection
VRF heat recoveryMixed-use buildings with simultaneous demandUp to 64Yes, per zoneMid – highBranch-box design has to be right first time
Close controlComms rooms, labs, pharmaceutical storage1 – 4Rarely neededHighRedundancy and alarms are the point — don't value-engineer them out

Costs are relative, not quoted. Every job is priced after a free survey.

What a proper survey looks at

Heat gain

Floor area, glazing and orientation, occupancy, lighting, equipment and fresh air. Sized to the peak, not the average, so the system isn't short on the day it matters.

Electrical capacity

Incoming supply, spare ways on the board and cable routes. Found at survey, not on install day.

Pipe and condensate routes

How far the refrigerant pipe runs, how many bends, and where condensate drains to. Long or lifted runs affect capacity and are allowed for.

Outdoor unit position

Airflow clearance, noise to neighbours, planning considerations and access for maintenance — and whether it needs a frame, a cage or a roof check.

Typical sectors

Offices, retail, healthcare, education, data and comms rooms, industrial units, and high-specification residential.

Worth knowing

If you already know the room dimensions, the sizing calculator will give you an indicative kW requirement in seconds.